The modular air cooled chiller and heat pump is designed for cooling and heating operations in large commercial and industrial buildings. The chiller and heat pumps will often be installed in malls, hotels, hospitals,and office buildings. The machine set can be installed on the roofs balconies,courtyards,and other suitable outdoor positions. The equipment does not need to be installed in a specially built water chiller machine room.
Advantage of product:
Product | Air cooed water chiller and heat pump- Scroll compressor | |||||||||
Type | Modular | |||||||||
Model | RLSFWM68 | RLSFWM90 | RLSFWM136 | RLSFWM204 | RLSFWM272 | RLSFWM340 | RLSFWM408 | RLSFWM476 | ||
Cooling capacity | kW | 68 | 86 | 136 | 204 | 272 | 340 | 408 | 476 | |
Cooling inpurt power | kW | 21.1 | 16 | 42.2 | 63.2 | 84.3 | 105.4 | 126.5 | 147.6 | |
Running current | A | 41.2 | 17.4 | 82.4 | 123.6 | 164.8 | 206 | 247.2 | 288.4 | |
Heating capacity | kW | 70 | 92.4 | 140 | 140 | 140 | 140 | 140 | 140 | |
Heating power | kW | 22.1 | 15.8 | 44.1 | 66.2 | 88.2 | 110.3 | 132.4 | 154.4 | |
Running current | A | 39.5 | 24 | 79 | 118.5 | 158 | 197.5 | 237 | 276.5 | |
Max. running current | A | 48.2 | 71 | 96.4 | 144.6 | 192.8 | 241 | 289.2 | 337.4 | |
Power supply | 380v/ 3ph / 50hz | |||||||||
Compressor | Type | Hermetic scroll type | ||||||||
Quantity | 2 | 2 | 4 | 6 | 8 | 10 | 12 | 14 | ||
Start mode | Direct start | |||||||||
Regrigerant | Type | R410a | ||||||||
Charge (kg) | 11.5x2 | 12*2 | 11.5x4 | 11.5x6 | 11.5x8 | 11.5x10 | 11.5x12 | 11.5x14 | ||
Control | EXV | |||||||||
Evaporator | Type | Shell-tube | ||||||||
Pressure drop | kPa | 70 | ||||||||
Main water pipe connection size | DN50 | DN65 | DN50*2 | DN50*3 | DN50*4 | DN50*5 | DN50*6 | DN50*7 | ||
Water flow | m3/h | 11.7 | 13.4 | 23.4 | 35.1 | 46.8 | 58.5 | 70.2 | 81.9 | |
Dimension | L | mm | 2110 | 2370 | 2110 | 2110 | 2110 | 2110 | 2110 | 2110 |
W | mm | 1080 | 1190 | 2160 | 3240 | 4320 | 5400 | 6480 | 7560 | |
H | mm | 1870 | 2270 | 1870 | 1870 | 1870 | 1870 | 1870 | 1870 | |
Net weight | kg | 700 | 900 | 1400 | 2100 | 2800 | 3500 | 4200 | 4900 | |
Operation weight | kg | 760 | 980 | 1520 | 2280 | 3040 | 3800 | 4560 | 5320 | |
Noise | dB(A) | 73 | 73 | 73 | 73 | 74 | 74 |
The Difference Between Ultra-low Temperature Air Energy Heat Pump and Ordinary Air Energy Heat Pump
Q1: Can you meet customer requirements for the brands and voltages of motors and compressors? |
A1: Yes, we can customize the motor and compressor brands as well as the operating voltage according to your local standards and specific requirements. Just let us know your preferences during the inquiry. |
Q2: How can I get the price of AHU? |
A2: To provide an accurate price, please share the technical specifications such as airflow (CMH or CFM), cooling/heating capacity, application area, and any special requirements. Our team will then prepare a tailored quotation for you. |
Q3: What is the difference between water-cooled and air-cooled units? |
A3: Water-cooled units use water as the cooling medium and require a cooling tower. They are more efficient but need additional water supply systems. Air-cooled units use ambient air to dissipate heat and are easier to install and maintain, making them suitable for areas with water scarcity or limited infrastructure. |
Q4: I have a factory/room/hotel with an area of about 500m² and a height of 3m. How much airflow of AHU is suitable for me? |
A4: For a 500m² area with 3m height, the total volume is 1500 m³. Typically, air changes per hour (ACH) range from 5 to 15 depending on the usage. Based on an average of 10 ACH, you would need an AHU with an airflow of approximately 15,000 m³/h. We can adjust based on your specific application. |
Q5: What compressors are commonly used in your refrigeration units? |
A5: We commonly use well-known brands such as Bitzer, Copeland, Danfoss, and Sanyo. The selection depends on your cooling capacity requirements and voltage preferences. |
Q6: We want to have our company's logo on the product, can you please? |
A6: Absolutely! We support OEM services, including applying your company logo on the product body, nameplate, and packaging upon request. |
Q7: What is the panel material of the AHU? |
A7: Our AHU panels are typically made of double-skin galvanized steel with polyurethane insulation (thickness of 25-50mm). Optional materials include stainless steel or aluminum alloy, depending on corrosion resistance and hygiene requirements. |
Q8: What kind of units is suitable for airports, exhibition halls, and large industrial plants? |
A8: For large open spaces like airports and exhibition halls, we recommend modular AHUs, rooftop packaged units, or large-capacity central air conditioning systems with high airflow and cooling capacities, capable of handling high occupancy and heat loads. |
Q9: Can you select the unit according to the room area? |
A9: Yes, we can help you select the most suitable unit based on your room area, usage type, ceiling height, and environmental conditions. Please provide these details for accurate sizing. |
Q10: What is the difference between a fresh air unit and an air conditioning unit? |
A10: A fresh air unit focuses on supplying filtered outdoor air into the space, improving air quality and oxygen levels. It does not regulate temperature. An air conditioning unit, on the other hand, controls both temperature and humidity, often recirculating indoor air. Some systems combine both functions. |