• Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner
  • Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner
  • Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner
  • Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner
  • Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner
  • Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner

Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner

After-sales Service: Overseas After-Sales Department
Warranty: 5years
Type: Chiller
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner pictures & photos
Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner
US $2,800-13,000 / Set
Min. Order: 1 Set
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Shandong, China
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Full Customization
The supplier provides full customization services
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (22)

Basic Info.

Model NO.
DCT-451
Air Tube Material
Galvanized Sheet
Corrosion Durability
Ultrahigh
Operating Voltage
380/400 VAC
Noise Level
Ultra Low
Application Fields
Mechanical Engineering
Mounting
Floor Standing
Lifetime
>20 years
Certification
ISO, CE, CCC
Condition
New
Model
Rlsfwm68
Cooling Capacity
68kw
Cooling Inpurt Power
21.1kw
Running Currentq
41.2A
Heating Capacity
70kw
Heating Power
22.1kw
Compressor Type
Hermetic Scroll Type
Compressor Quantity
2
Start Mode
Direct Start
Refrigerant Type
R410A
Evaporator Type
Shell-Tube
Evaporator Pressure Drop
70kpa
Main Water Pipe Connection Size
DN50
Water Flow
11.7m3/H
Dimension
2110*1080*1870mm
Transport Package
Naked
Specification
4200*2000*2000mm
Trademark
DECENT
Origin
China
HS Code
8418692090
Production Capacity
10000 Sets/ Year

Packaging & Delivery

Package Size
2000.00cm * 4000.00cm * 6000.00cm
Package Gross Weight
6000.000kg
Lead Time
10 days (1 - 5 Sets)
20 days (6 - 15 Sets)
30 days (16 - 20 Sets)
To be negotiated ( > 20 Sets)

Product Description

Ultra-low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump

The modular air cooled chiller and heat pump is designed for cooling and heating operations in large commercial and industrial buildings. The chiller and heat pumps will often be installed in malls, hotels, hospitals,and office buildings. The machine set can be installed on the roofs balconies,courtyards,and other suitable outdoor positions. The equipment does not need to be installed in a specially built water chiller machine room.
Advantage of product:

1. Easy to install and save space. 
2. 100% heat recovery is for optional.
3. Modular design. Each cooling system operates independently of the others.
4. Equipment can be fully assembled on site. Standard modules are light weight and take up little space.
5. In accordance with the requirements and needs for cooling / heating the client, we create various combinations of modules.
6. In the process of starting the operation of the equipment, the alternate start of the compressors is carried out using a computer, which reduces the current impact on the power supply network.
Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner
Product Air cooed water chiller and heat pump- Scroll compressor
Type Modular
Model RLSFWM68 RLSFWM90 RLSFWM136 RLSFWM204 RLSFWM272 RLSFWM340 RLSFWM408 RLSFWM476
Cooling capacity kW 68 86 136 204 272 340 408 476
Cooling inpurt power kW 21.1 16 42.2 63.2 84.3 105.4 126.5 147.6
Running current A 41.2 17.4 82.4 123.6 164.8 206 247.2 288.4
Heating capacity kW 70 92.4 140 140 140 140 140 140
Heating power kW 22.1 15.8 44.1 66.2 88.2 110.3 132.4 154.4
Running current A 39.5 24 79 118.5 158 197.5 237 276.5
Max. running current A 48.2 71 96.4 144.6 192.8 241 289.2 337.4
Power supply 380v/ 3ph / 50hz      
Compressor Type Hermetic scroll type      
Quantity 2 2 4 6 8 10 12 14
Start mode Direct start
Regrigerant Type R410a
Charge (kg) 11.5x2 12*2 11.5x4 11.5x6 11.5x8 11.5x10 11.5x12 11.5x14
Control EXV
Evaporator Type Shell-tube
Pressure drop kPa 70
Main water pipe connection size DN50 DN65 DN50*2 DN50*3 DN50*4 DN50*5 DN50*6 DN50*7
Water flow m3/h 11.7  13.4  23.4  35.1  46.8  58.5  70.2  81.9 
Dimension L mm 2110 2370 2110 2110 2110 2110 2110 2110
W mm 1080 1190 2160 3240 4320 5400 6480 7560
H mm 1870 2270 1870 1870 1870 1870 1870 1870
Net weight kg 700 900 1400 2100 2800 3500 4200 4900
Operation weight kg 760 980 1520 2280 3040 3800 4560 5320
Noise dB(A) 73 73 73 73 74 74
 

The Difference Between Ultra-low Temperature Air Energy Heat Pump and Ordinary Air Energy Heat Pump

  1. The operating conditions of the two are different
    We all know that the working principle of the air energy heat pump is to convert the heat in the air into the available high heat energy through the compressor, and then exchange it with the water system to provide hot water, heating, cooling, drying and other purposes. The temperature environment in which the ordinary air source heat pump operates is preferably within minus 10 ºC. If it operates at minus 10 to 25 ºC, it may appear:
  2. Compressor is prone to failureThe temperature of the exhaust gas rises rapidly, and the overheating of the working medium is too high. In the case of overheating of the working medium, the thermal conductivity of the working medium in the condenser decreases sharply, and at the same time, the temperature of the lubricating oil increases and the viscosity decreases, which affects the normal lubrication of the compressor.
  3. The unit cannot defrostIn frequent rain and snow weather and low temperature, the defrosting ability of the unit is easily weakened. Because the air intake of the unit is too small, the density of the air that can be inhaled is reduced. With the accumulation of time, the thickness of the frost layer is getting higher and higher. Therefore, the unit will reduce the circulation of the refrigerant due to the decrease in the air conversion capacity, and the overall heating capacity will decrease.
Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner
  1. Ultra-low Temperature air Energy Operation Technology
    Air energy heat pump manufacturers have their own ultra-low temperature technology. Since the air energy heat pump host is generally installed outdoors, the phenomenon of frost will frequently occur in rainy and snowy weather. The ultra-low temperature air energy heat pump host can intelligently judge the defrosting needs, and intelligently judge whether to defrost according to the operating conditions of the unit (running time, exhaust temperature, etc.), combined with the ambient temperature and frost thickness. Defrost with frost and no defrost without frost, greatly extending the defrosting cycle, shortening the defrosting time by 20%, and ensuring the efficient operation of the unit
  2. Jet Enthalpy Technology Because the heating efficiency of the air-energy heat pump in extremely cold weather will be greatly attenuated, resulting in an unsatisfactory heating effect.The ultra-low temperature air energy heat pump uses the jet enthalpy increase technology to create a second suction port on the scroll, and through the second suction circuit, the refrigerant flow is increased, and the circulation volume of the unit is increased during cooling.Compared with the general unit, the cooling capacity is increased by 10%, which greatly improves the refrigerant circulation system, makes full use of the refrigerant flow and utilization rate in the compressor, and improves the stability of the system operation and the heating efficiency.
  3. Shell and Tube Heat Exchanger,Ordinary air can use plate heat exchanger, which is easy to scale and block the flow passage. Lowtemperature air can use copper tube with internal thread and external fins. Water inside the tube and fluorine outside the tube. The heat exchange area is large and the heat exchange efficiency is high.
Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air ConditionerUltra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner pictures & photos
Ultra-Low Temperature Air Energy Industrial Modular Air Cooled Water Chiller and Heat Pump Air Conditioner
US $2,800-13,000 / Set
Min. Order: 1 Set
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001, QC 080000