High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan

Product Details
Customization: Available
Type: Tunnel Fan
Mounting: Free Standing
Still deciding? Get samples of US$ 2998/Piece
Request Sample
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Full Customization
The supplier provides full customization services
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (24)
  • High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan
  • High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan
  • High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan
  • High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan
  • High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan
  • High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan
Find Similar Products

Basic Info.

Model NO.
DCT-779
Voltage
380V/410V/440V/3kv/6kv
Motor
ABB, Siemens Brand
Color
Customizable
Applicable Industries
Hotels, Manufacturing Plant, Machinery
Diameter
40mm - 3000mm
Impeller Testing
Dynamic Blancing Adjusting
Power Source
Electricity
Electricity
Tiny Vibration
Warranty
2 Years
Selling Units
Single Item
Supply Ability
1000
Shape
Customizable
Transport Package
Wooden Packing
Specification
200X100X50 cm
Trademark
DECENT
Origin
Shandong, China
HS Code
8414593000
Production Capacity
10000 Sets/ Year

Product Description

We offer our customers a wide range of different systems of tunnel ventilation, starting from 315 up to 2.500 mm.The DECENT tunnel jet fan series are available as unidirectional or reversible units. All versions include silencers. The range of sizes and capacities cover medium to high thrusts.We believe in building on the best, and therefore our Total Mine Ventilation Solution is built upon the worlds best OEM ventilation equipmentDCT-60Ventilation system designs with tunnel jet fans are ductless and may include auxiliary fans for supply and exhaust of air.Blower is also commonly known as Centrifugal Fans in industry. In a blower, the inlet pressure is low and is higher at the outlet.Axial-Flow Exhaust Poultry Farm Tunnel Axial Mining Ventilation Fans

High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan
High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan


High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan


High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan


High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan

High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan
High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan

High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan

 

  • Application: Best choise ventilation fan for under mining coal and tunnel
  • Function: big power ventilation, low noisy, high efficiency, energy-saving, various style available
  • Structure: single vane, single motor
  • With ABB MOTOR

The main components of the main body casing, impeller and explosionproof motor. The chassis is bearing the main body, the main role is to ensure the normal operation of the impeller and motor concurrently, since the role of the muffler. The impeller is the master generates airflow core member, the motor is so that the driving force of the rotation of the impeller member. Its working principle is that the airflow into the host body along the axial flow into the impeller, deflected accelerated after the direction of the flow into the next unit;

Diffuser diffusion tube and shroud, the main role is to reduce airflow export loss of local resistance, improve ventilator effective acting ability, airflow through it discharged axially fan, at the same time, and play the role of the muffler.

 Performanc

The following datas are only part of performance of our product of thousands kinds.

If you can't find the datas you need, pls send us your performance requirements,

we will provide you customized design service in 8 hours.You can view our website at:http://decent.en.made-in-china.com 

YBT/FBY Copper/Coal/ explosion-proof / underground/ tunnel /mine/ fan 

 

Model 
 
YBT/FBY-2.2 YBT/FBY-5.5 YBT/FBY-7.5 YBT/FBY-11 YBT/FBY-18.5 YBT/FBY-22 YBT/FBY-30
Full pressure (Pa) 960-380 1700-800 1900-900 2250-800 2400-520 3200-680 3500-800
Air capacity (mmin) 55-101 90-180 100-210 130-240 195-300 240-370 250-800
Efficiency (%) 76 76 80 80 80 80.0 80
dB(A) Level 87 89 89 91 95 95 95
Diameter (mm) 315 400 500 560 600 600 630
Power (KW) 2.2 5.5 7.5 11 18.5 22 30

YBT/FBY Copper/Co 


High Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent FanHigh Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent FanHigh Quality Large Volume Fbd Decent Exhaust Ventilation 75kw Mine Vent Fan