Secured Trading Service

Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223

Decent Machinery Co., Ltd.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Product Highlights

  • High-Efficiency Heat Exchange: Copper tube + corrugated aluminum fin design for efficient heat exchange and low water resistance.
  • Energy-Saving Heat Recovery: Reclaims thermal energy from exhaust air to reduce HVAC consumption and CO2 emissions.
  • Stable and Durable Structure: Modular frame with double-layer steel panels and insulation for minimal air leakage.
  • Air Purification & Sterilization: Enhanced antibacterial features and sterilization device meeting GMP and hospital standards.
  • Customized Color Options: Color is fully customizable to meet specific aesthetic requirements.
  • Flexible Configuration: Supports various fan types, filter classes, and humidifier types for tailored solutions.
  • Wide Application Scope: Suitable for stadiums, airports, hospitals, and industries like food, pharma, and textiles.
  • Comprehensive Certifications: Certified with ISO, CE, CCC, RoHS, and UR for global market compliance.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223

Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223 pictures & photos
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223 pictures & photos
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223 pictures & photos
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223 pictures & photos
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223 pictures & photos
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223 pictures & photos
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
  • Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
  • Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
    Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
  • Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
    Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
  • Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
    Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
  • Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
    Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
  • Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
    Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
  • Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
    Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223

Find Similar Products

Product Description



Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
Product Description

This series of modular air handling units integrates high-efficiency heat exchange, energy-saving heat recovery, and intelligent control, offering advantages such as stable operation, flexible configuration, and easy maintenance. It is widely used in stadiums, exhibition centers, airports, large railway stations, and industrial facilities (including automotive, electronics, textiles, pharmaceuticals, tobacco, precision instruments, etc.) as well as high-cleanliness environments (such as hospitals, pharmaceutical production, biotechnology, food processing, and chemical industries).
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223

Detailed Photos
High-Efficiency Heat Exchange: Adopts a copper tube + corrugated aluminum fin design, scientifically optimizing fin spacing and water circuit layout for efficient heat exchange, low water resistance, and long service life.
Stable and Durable: The unit casing features a modular, disassemblable frame structure, constructed with double-layer premium steel panels and polyurethane foam or polystyrene insulation, ensuring strong sealing, minimal air leakage, and long-term stable operation.
Air Purification & Sterilization: The purification series is designed with enhanced antibacterial features and equipped with a high-efficiency sterilization device, effectively controlling internal bacterial and dust contamination. It meets stringent cleanliness standards for GMP, hospital operating rooms, and biotechnology laboratories.
Energy-Saving Heat Recovery: The energy recovery modular air handling unit integrates heat recovery technology, effectively reclaiming thermal energy from exhaust air, significantly reducing HVAC energy consumption, lowering CO2 emissions, and improving air quality to create a healthy and comfortable indoor environment.
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
Decent Projects

Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223

Product Parameters
Model NO. DMC-115WK Corrosion Durability Ultrahigh
Operating Voltage 380/400 VAC Noise Level Ultra Low
Application Fields Food Processing Mounting Floor Standing
Lifetime 15~20 years Certification RoHS, UR, ISO, CE, CCC
Condition New Model Asm-028
Cooling Capacity 130-314 Input Power 45.5-107.5
Noise 72--74 dB(a) Rated Current 73.4-173.5
Dimension 2080*2200*2200mm Eer 2.86-2.92
Feature Heat Recovery Energy Saving MOQ 1
Compressor Semi-Hermitic Double Screw Type Power 380V-3p-50Hz
Mechanical Test Report Provided Video Factory Inspect Provided
Video Technical Support Yes Online Support Yes
Transport Package Standard Specification Standard
Trademark DECENT Origin China
HS Code 8415830000 Production Capacity 10000 Sets/ Year
  8415822090    
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223
Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223


Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223

Packaging & Shipping

Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223

Company Profile

Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223Customized G4+F7+H10+H13 Heat Recovery Unit Decent Exchanger Industrial Air Chiller Mechanicalhvac System DCT-223

FAQ
Q1: Can you meet customer requirements for the brands and voltages of motors and compressors?
A1: Yes, we can customize the motor and compressor brands as well as the operating voltage according to your local standards and specific requirements. Just let us know your preferences during the inquiry.
Q2: How can I get the price of AHU?
A2: To provide an accurate price, please share the technical specifications such as airflow (CMH or CFM), cooling/heating capacity, application area, and any special requirements. Our team will then prepare a tailored quotation for you.
Q3: What is the difference between water-cooled and air-cooled units?
A3: Water-cooled units use water as the cooling medium and require a cooling tower. They are more efficient but need additional water supply systems. Air-cooled units use ambient air to dissipate heat and are easier to install and maintain, making them suitable for areas with water scarcity or limited infrastructure.
Q4: I have a factory/room/hotel with an area of about 500m² and a height of 3m. How much airflow of AHU is suitable for me?
A4: For a 500m² area with 3m height, the total volume is 1500 m³. Typically, air changes per hour (ACH) range from 5 to 15 depending on the usage. Based on an average of 10 ACH, you would need an AHU with an airflow of approximately 15,000 m³/h. We can adjust based on your specific application.
Q5: What compressors are commonly used in your refrigeration units?
A5: We commonly use well-known brands such as Bitzer, Copeland, Danfoss, and Sanyo. The selection depends on your cooling capacity requirements and voltage preferences.
Q6: We want to have our company's logo on the product, can you please?
A6: Absolutely! We support OEM services, including applying your company logo on the product body, nameplate, and packaging upon request.
Q7: What is the panel material of the AHU?
A7: Our AHU panels are typically made of double-skin galvanized steel with polyurethane insulation (thickness of 25-50mm). Optional materials include stainless steel or aluminum alloy, depending on corrosion resistance and hygiene requirements.
Q8: What kind of units is suitable for airports, exhibition halls, and large industrial plants?
A8: For large open spaces like airports and exhibition halls, we recommend modular AHUs, rooftop packaged units, or large-capacity central air conditioning systems with high airflow and cooling capacities, capable of handling high occupancy and heat loads.
Q9: Can you select the unit according to the room area?
A9: Yes, we can help you select the most suitable unit based on your room area, usage type, ceiling height, and environmental conditions. Please provide these details for accurate sizing.
Q10: What is the difference between a fresh air unit and an air conditioning unit?
A10: A fresh air unit focuses on supplying filtered outdoor air into the space, improving air quality and oxygen levels. It does not regulate temperature. An air conditioning unit, on the other hand, controls both temperature and humidity, often recirculating indoor air. Some systems combine both functions.

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR245102". Items marked "verified" are certified.

Watch Video
Watch Video
Decent Machinery Co., Ltd.
Decent Machinery Co., Ltd.
Decent Machinery Co., Ltd.
Decent Machinery Co., Ltd.
Decent Machinery Co., Ltd.
Decent Machinery Co., Ltd.
Decent Machinery Co., Ltd.
Decent Machinery Co., Ltd.

About Our Factory & Business Background

Address
Lijia Industrial Park, Nanjiao Town, Zohucun District, Zibo, Shandong, China
verified Terms of Payment
LC, T/T, D/P, PayPal, Small-amount payment, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Qingdao port
verified Minimum Order Quantity
1
verified Supply Chain Partners
50

Our Production Capability & Technical Expertise

Main Products
Ahu, Air Handling Unit, Mine Fan, Centrifugal Fan, Centrifugal Blower, Dust Collector, Tunnel Fan, Chiller, Mining Ventilation, Multistage Centrifugal Fan
verified Production Lines
2
verified Production Machines
Confidential
verified QA/QC inspectors
1 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified R&D Engineers
1 people
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Export Year
8 years
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Number of Foreign Trading Staff
12
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015

FAQ

Can you meet customer requirements for the brands and voltages of motors and compressors?
Yes, we can customize the motor and compressor brands as well as the operating voltage according to your local standards and specific requirements. Just let us know your preferences during the inquiry.
How can I get the price of AHU?
To provide an accurate price, please share the technical specifications such as airflow (CMH or CFM), cooling/heating capacity, application area, and any special requirements. Our team will then prepare a tailored quotation for you.
What is the difference between water-cooled and air-cooled units?
Water-cooled units use water as the cooling medium and require a cooling tower. They are more efficient but need additional water supply systems. Air-cooled units use ambient air to dissipate heat and are easier to install and maintain, making them suitable for areas with water scarcity or limited infrastructure.
We want to have our company's logo on the product, can you please?
Absolutely! We support OEM services, including applying your company logo on the product body, nameplate, and packaging upon request.
What is the panel material of the AHU?
Our AHU panels are typically made of double-skin galvanized steel with polyurethane insulation (thickness of 25-50mm). Optional materials include stainless steel or aluminum alloy, depending on corrosion resistance and hygiene requirements.
What kind of units is suitable for airports, exhibition halls, and large industrial plants?
For large open spaces like airports and exhibition halls, we recommend modular AHUs, rooftop packaged units, or large-capacity central air conditioning systems with high airflow and cooling capacities, capable of handling high occupancy and heat loads.
Can you select the unit according to the room area?
Yes, we can help you select the most suitable unit based on your room area, usage type, ceiling height, and environmental conditions. Please provide these details for accurate sizing.
What is the difference between a fresh air unit and an air conditioning unit?
A fresh air unit focuses on supplying filtered outdoor air into the space, improving air quality and oxygen levels. It does not regulate temperature. An air conditioning unit, on the other hand, controls both temperature and humidity, often recirculating indoor air. Some systems combine both functions.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now